Products over $50 Collection - (25001 Products)


Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 24 VDC, 48 VDC, 80 VDC, 1 Pole, Bolt On Miniature Circuit Breaker - Thermal Magnetic Trip, 14-4 AWG, 2-3/8 Inch Deep x 2-15/16 Inch High x 1 Inch Wide


Item #: 04882270
Brand: Eaton Cutler-Hammer
Model #: BAB1050
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 50
Number of Poles 1
Tripping Mechanism Thermal-Magnetic
Mounting Type Bolt-on
Voltage 120/240 VAC; 24 VDC; 48 VDC; 80 VDC
Wire Size (AWG) 14-4
Overall Depth (Inch) 2-3/8
Overall Height (Inch) 2-15/16
Overall Width (Inch) 1
Standards Met CSA Listed; Federal Specification W-C-375b; UL Listed 489

$81.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 20 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-3/0 AWG, 87.4mm Deep x 162.6mm High x 104.7mm Wide


Item #: 69647717
Brand: Square D
Model #: HGL36020
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 20
Number of Poles 3
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 104
Overall Depth (Decimal Inch) 3.4400
Overall Depth (mm) 87.40
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With Communication Network; Front Display Module; Operating Assistance; Power Meter
Standards Met CSA Certified; IEC 647-2 Icu/Ics; NOM; UL Listed
Reset Actuator Type Toggle Switch

$1,701.84

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56744360
Brand: Square D
Model #: JDL36200C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0

$2,823.95

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 45 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399403
Brand: Square D
Model #: BDA36045
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 45
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,270.94

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 60 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide


Item #: 56837438
Brand: Square D
Model #: QOUR160
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 60
Number of Poles 1
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9200
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 19
Overall Width (Decimal Inch) 3/4
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$56.78

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 20 Amp, 440 VAC, 2 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 36mm Wide


Item #: 56838295
Brand: Schneider Electric
Model #: M9F14220
Exact Tooling IR#: 04

Features and Benefits

Magnetic tripping mechanisms are designed with a solenoid (electromagnet), which will quickly disconnect in case of a short circuit or overload. They are not greatly affected by extreme environmental conditions, but are sensitive to low-overloads.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 20
Number of Poles 2
Breaking Capacity 10 kA @ 440 VAC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mounted
Voltage 440 VAC
Wire Size (sq mm) 1-25
Wire Size (AWG) 18-4
Durability 10000 Cycles
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Depth (Decimal Inch) 3
Overall Depth (mm) 76
Overall Height (mm) 81
Overall Height (Decimal Inch) 3.1900
Overall Width (mm) 36
Overall Width (Decimal Inch) 1.4200
For Use With Multi 9 Modular System
Standards Met IEC Certified; UL Listed; UL Recognized
Reset Actuator Type Toggle Switch

$288.59

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 600 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG


Item #: 54522560
Brand: Square D
Model #: LJL36600U31X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 600
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 2
Standards Met CCC; CSA; IEC; RoHS Compliant; UL Listed

$11,179.57

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 400 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 2 AWG


Item #: 56766223
Brand: Square D
Model #: LGL36400U43X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 400
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 2
Standards Met CCC; CSA; IEC; RoHS Compliant; UL Listed

$7,702.92

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 60 Amp, 120/240 VAC, 2 Pole, Plug In Type BR Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 8-1/0 AWG


Item #: 00105262
Brand: Eaton Cutler-Hammer
Model #: BR260
Exact Tooling IR#: 04

Features and Benefits

Type BR circuuit breakers are used in load centers, panelboards, or similar devices. They are available in 1,2 or with 3 poles.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Type BR Circuit Breaker
Amperage 60
Number of Poles 2
Breaking Capacity 10 kA
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Plug-in
Voltage 120/240 VAC
Wire Size (AWG) 8-1/0
Standards Met NEC 2008; NEC 2011; NEC 2014; UL Listed 67

$70.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 10 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 54540729
Brand: Schneider Electric
Model #: GV2RT14
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 10
Number of Poles 3
Breaking Capacity 10 kA @ 500 VAC; 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 15 kA @ 440 VAC; 3 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$230.56

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56739758
Brand: Square D
Model #: HDL26090
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 90
Number of Poles 2
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0

$983.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 90 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56747603
Brand: Square D
Model #: HDL36090AA
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 90
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$1,901.75

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 70 Amp, 250 VDC, 600 VAC, 3 Pole, Individually Mounted Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 600 VAC Breaking Capacity, 12-1/0 (Aluminum), 14-1/0 (Copper) AWG, 4.13 Inch Deep x 6 Inch High x 4-1/2 Inch Wide


Item #: 56769342
Brand: Square D
Model #: FHP36070TF
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 70
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Individually-Mounted
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 12-1/0 (Aluminum); 14-1/0 (Copper)
Overall Depth (Decimal Inch) 4.1300
Overall Height (Decimal Inch) 6
Overall Width (Decimal Inch) 4-1/2
For Use With I-Line Panelboards & Switchboards
Standards Met CSA Certified; Federal Specification W-C 375 b/Gen; IEC Rated; UL Listed
Reset Actuator Type Toggle Switch

$2,162.71

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 4 Amp, 690 VAC at 50/60 Hz, 3 Pole, Bolt On, Clip Motor Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 78mm Deep x 89mm High x 45mm Wide


Item #: 69648749
Brand: Schneider Electric
Model #: GV2RT08
Exact Tooling IR#: 04

Features and Benefits

Motor Circuit breakers are used for protecting motor branch circuits from overloads, phase loss and short circuits. They can be configured in low voltage circuit breakers and magnetic motor starters.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Motor Circuit Breaker
Amperage 4
Number of Poles 3
Breaking Capacity 100 kA @ 220/230 VAC; 100 kA @ 400/415 VAC; 100 kA @ 440 VAC; 100 kA @ 500 VAC; 3 kA @ 690 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Mounting Type Bolt-on; Clip
Voltage 690 VAC @ 50/60 Hz
Durability 100000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 78
Overall Height (mm) 89
Overall Width (mm) 45
For Use With TeSys GV2
Standards Met ATEX; Bureau Veritas; CCC; CEBEC; CSA; DNV; EZU; GL; GOST; IEC 60947-2; LROS; RINA; SETI; TSE; UL

$220.56

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 20 Amp, 125 VDC, 240 VAC, 1 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide


Item #: 04882908
Brand: Eaton Cutler-Hammer
Model #: EHD1020L
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 20
Number of Poles 1
Breaking Capacity 18 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Voltage 125 VDC; 240 VAC
Wire Size (AWG) 14-1/0
Overall Depth (Decimal Inch) 3.3800
Overall Depth (Inch) 3-3/8
Overall Height (Decimal Inch) 6
Overall Width (Inch) 4-1/8
Standards Met CSA Listed; UL Listed 1053; UL Listed 489

$298.19

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 0.50 Amp, 2 Pole, Backplate, Clip, DIN Rail Mount Circuit Protector - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 70mm Deep x 74mm High x 30mm Wide


Item #: 56804396
Brand: Schneider Electric
Model #: GB2DB05
Exact Tooling IR#: 04

Features and Benefits

Circuit protectors are designed for protecting relays, motors, heaters, transformers, solenoids and semiconductors from short circuiting. They protect by monitoring the flow of electricity and detecting any imbalances in the electrical device.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Circuit Protector
Amperage 0.50
Number of Poles 2
Breaking Capacity 1 kA @ 48 VDC; 1.5 kA @ 24 VDC; 50 kA @ 110 VAC; 50 kA @ 230/240 VAC; 50 kA @ 400/415 VAC
Tripping Mechanism Thermal-Magnetic
Mounting Type Backplate; Clip; DIN Rail Mount
Durability 8000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -4
Overall Depth (mm) 70
Overall Height (mm) 74
Overall Width (mm) 30
Reset Actuator Type Toggle Switch

$113.48

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 35 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 100 kA at 240 VAC, 65 kA at 480 VAC, 25 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41396912
Brand: Square D
Model #: BJL26035LU
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 35
Number of Poles 2
Breaking Capacity 100 kA @ 240 VAC; 65 kA @ 480 VAC; 25 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Reset Actuator Type Toggle Switch

$1,239.37

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG


Item #: 41393711
Brand: Square D
Model #: BDL36015
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 15
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-3/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type Toggle Switch

$997.29

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 800 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 18 kA at 600 VAC Breaking Capacity, 3/0 (Aluminum), 3/0 (Copper) AWG, 8.05 Inch Deep x 16.16 Inch High x 8.27 Inch Wide


Item #: 56767783
Brand: Square D
Model #: GP46080U33AABJK
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 800
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 3/0 (Aluminum); 3/0 (Copper)
Overall Depth (Decimal Inch) 8.0500
Overall Height (Decimal Inch) 16.1600
Overall Width (Decimal Inch) 8.2700
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$22,887.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2000 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56761570
Brand: Square D
Model #: RGF36200CU31A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 2000
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Electronic
Terminal Connection Type Screw
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$41,009.73