Products over $50 Collection - (25001 Products)
Square D - 100 Amp, 690 VAC, 4 Pole, Backplate, Fixed Mount Molded Case Compact Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 161mm High x 140mm Wide
Item #: 56739089
Brand: Square D
Model #: LV429572
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Compact Circuit Breaker
Amperage
100
Number of Poles
4
Breaking Capacity
15 kA @ 500 VAC; 20 kA @ 440 VAC; 20 kA @ 480 VAC; 25 kA @ 380/415 VAC; 40 kA @ 220/240 VAC; 40 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Backplate; Fixed Mount
Voltage
690 VAC
Durability
50000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-31
Overall Height (mm)
161
Overall Width (mm)
140
Standards Met
CSA; EN/IEC 60947-2; NEMA AB1; RoHS Compliant; UL 508; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 60 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide
Item #: 56740889
Brand: Square D
Model #: HDM36060
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
60
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
Overall Depth (Decimal Inch)
4.3600
Overall Depth (mm)
110.80
Overall Height (mm)
162.60
Overall Height (Decimal Inch)
6.4000
Overall Width (mm)
104.70
Overall Width (Decimal Inch)
4.1200
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 63 Amp, 250 VDC, 1 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2, 18-4, 18-6 AWG
Item #: 46117149
Brand: Schneider Electric
Model #: M9U21163
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
63
Number of Poles
1
Breaking Capacity
10 kA @ 220 VDC; 6 kA @ 250 VDC; 20 kA @ 110 VDC; 5 kA @ 12-250 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
250 VDC
Wire Size (AWG)
18-2; 18-4; 18-6
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 32 Amp, 690 VAC, 3 Pole, Fixed Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 86mm Deep x 161mm High x 105mm Wide
Item #: 56760820
Brand: Square D
Model #: LV429635
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
32
Number of Poles
3
Breaking Capacity
10 kA @ 600 VAC; 22 kA @ 525 VAC; 25 kA @ 480 VAC; 25 kA @ 500 VAC; 35 kA @ 440 VAC; 35 kA @ 480 VAC; 36 kA @ 380/415 VAC; 8 kA @ 600 VAC; 8 kA @ 660/690 VAC; 85 kA @ 220/240 VAC; 85 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Fixed
Voltage
690 VAC
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-31
Overall Depth (mm)
86
Overall Height (mm)
161
Overall Width (mm)
105
Standards Met
CSA Certified; EN 60947-2; IEC 60947-2; NEMA AB1; UL 508; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 30 Amp, 120/240 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 240 VAC Breaking Capacity, 14-2 AWG, 76mm Deep x 81mm High x 18mm Wide
Item #: 56785942
Brand: Schneider Electric
Model #: 60215
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
30
Number of Poles
1
Breaking Capacity
10 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
120/240 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
14-2
Durability
4000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
18
Overall Width (Decimal Inch)
0.7100
Standards Met
CE Marked; CSA C22.2 No. 5.1 Circuit Breakers: File No. 179014; HID (High Intensity Discharge) Rated; IEC 60947-2; UL 489 Circuit Breakers: File No. E215117; UL Listed for SWD Applications
Reset Actuator Type
Handle
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 40 Amp, 440 VAC, 1 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 18mm Wide
Item #: 56786981
Brand: Schneider Electric
Model #: M9F14140
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
40
Number of Poles
1
Breaking Capacity
15 kA @ 230/240 VAC; 30 kA @ 130 VAC; 4 kA @ 400/415 VAC
Tripping Mechanism
Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
440 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
18-2
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
18
Overall Width (Decimal Inch)
0.7100
For Use With
Multi 9 Modular System
Standards Met
IEC Certified; UL Listed; UL Recognized
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 32 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-2 AWG, 76mm Deep x 81mm High x 54mm Wide
Item #: 56786908
Brand: Schneider Electric
Model #: M9F14332
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
32
Number of Poles
3
Breaking Capacity
10 kA @ 440 VAC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism
Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
440 VAC
Wire Size (sq mm)
1-35
Wire Size (AWG)
18-2
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
54
Overall Width (Decimal Inch)
2.1300
For Use With
Multi 9 Modular System
Standards Met
IEC Certified; UL Listed; UL Recognized
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 8 Amp, 480Y/277 Volt, 2 Pole, Clip Mount C60BP - Branch Protection Circuit Breaker - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG
Item #: 46120754
Brand: Schneider Electric
Model #: M9F42208
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60BP - Branch Protection
Amperage
8
Number of Poles
2
Breaking Capacity
6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC; 14 kA @ 240 VAC; 10 kA @ 125 VDC; 10 kA @ 480Y/277 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
480Y/277 V
Wire Size (AWG)
18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
4.0600
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
1.4200
For Use With
OEM Panel
Standards Met
UL 489; IEC; CSA; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 3 Amp, 440 VAC, 3 Pole, DIN Rail Mounted Miniature Circuit Breaker - Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4 AWG, 76mm Deep x 81mm High x 54mm Wide
Item #: 56838436
Brand: Schneider Electric
Model #: M9F15303
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
3
Number of Poles
3
Breaking Capacity
10 kA @ 440 VAC; 15 kA @ 400-415 VAC; 30 kA @ 230-240 VAC
Tripping Mechanism
Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
DIN Rail Mounted
Voltage
440 VAC
Wire Size (sq mm)
1-25
Wire Size (AWG)
18-4
Durability
10000 Cycles
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Depth (Decimal Inch)
3
Overall Depth (mm)
76
Overall Height (mm)
81
Overall Height (Decimal Inch)
3.1900
Overall Width (mm)
54
Overall Width (Decimal Inch)
2.1300
For Use With
Multi 9 Modular System
Standards Met
IEC Certified; UL Listed; UL Recognized
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 15 Amp, 250 VDC, 480 VAC, 2 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 18 kA at 240 VAC Breaking Capacity, 14-1/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04882924
Brand: Eaton Cutler-Hammer
Model #: EHD2015L
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
15
Number of Poles
2
Breaking Capacity
18 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 480 VAC
Wire Size (AWG)
14-1/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (Inch)
3-3/8
Overall Height (Decimal Inch)
6
Overall Width (Inch)
4-1/8
Standards Met
CSA Listed; UL Listed 1053; UL Listed 489
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 50 Amp, 120/240 VAC, 2 Pole, Plug In Type BR Circuit Breaker - Thermal Magnetic Trip, 10 kA Breaking Capacity, 14-4 AWG
Item #: 00105254
Brand: Eaton Cutler-Hammer
Model #: BR250
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Type BR Circuit Breaker
Amperage
50
Number of Poles
2
Breaking Capacity
10 kA
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Mounting Type
Plug-in
Voltage
120/240 VAC
Wire Size (AWG)
14-4
Standards Met
NEC 2008; NEC 2011; NEC 2014; UL Listed 67
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 25 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG
Item #: 69524205
Brand: Square D
Model #: HDL36025
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
25
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Panel Mount
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
14-3/0
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 15 Amp, 120/240 VAC, 2 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 19mm Wide
Item #: 56837453
Brand: Square D
Model #: QOUR2155283CCC
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Miniature Circuit Breaker
Amperage
15
Number of Poles
2
Breaking Capacity
10 kA @ 120/240 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Pressure Plate
Mounting Type
DIN Rail Mounted; Flush Mount; Surface Mount
Voltage
120/240 VAC
Wire Size (AWG)
14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch)
2.9200
Overall Depth (mm)
74
Overall Height (mm)
103
Overall Height (Decimal Inch)
4.0500
Overall Width (mm)
19
Overall Width (Decimal Inch)
3/4
For Use With
I-Line Panelboards & Switchboards
Standards Met
CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 25 Amp, 600Y/347 VAC, 3 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41393679
Brand: Square D
Model #: BDL36025
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
25
Number of Poles
3
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 35 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41384041
Brand: Square D
Model #: BGL26035LU
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
35
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 50 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 277 VAC, 14 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41393539
Brand: Square D
Model #: BDL26050
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
50
Number of Poles
2
Breaking Capacity
25 kA @ 240 VAC; 18 kA @ 277 VAC; 14 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 20 Amp, 277/480 VAC, 2 Pole, Bolt On Molded Case Circuit Breaker - Thermal Magnetic Trip, 14-10 AWG, 66.7mm Deep x 4 Inch High x 2 Inch Wide
Item #: 04882650
Brand: Eaton Cutler-Hammer
Model #: GHB2020
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
20
Number of Poles
2
Tripping Mechanism
Thermal-Magnetic
Mounting Type
Bolt-on
Voltage
277/480 VAC
Wire Size (AWG)
14-10
Overall Depth (Decimal Inch)
2.6300
Overall Depth (mm)
66.70
Overall Height (mm)
101.60
Overall Height (Inch)
4
Overall Width (Inch)
2
Standards Met
CSA Listed; UL Listed
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Eaton Cutler-Hammer - 125 Amp, 250 VDC, 600 VAC, 3 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 14 kA at 600 VAC Breaking Capacity, 4-4/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide
Item #: 04883120
Brand: Eaton Cutler-Hammer
Model #: FDB3125
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
Molded Case Circuit Breaker
Amperage
125
Number of Poles
3
Breaking Capacity
14 kA @ 600 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Screw
Voltage
250 VDC; 600 VAC
Wire Size (AWG)
4-4/0
Overall Depth (Decimal Inch)
3.3800
Overall Depth (mm)
85.70
Overall Depth (Inch)
3-3/8
Overall Height (mm)
152.40
Overall Height (Inch)
6
Overall Height (Decimal Inch)
6
Overall Length (mm)
152.40
Overall Width (mm)
104.90
Overall Width (Inch)
4-1/8
Overall Width (Decimal Inch)
4.1300
Standards Met
NEC Article 240.83(d); UL Listed for SWD Applications
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Square D - 90 Amp, 600Y/347 VAC, 2 Pole, Unit Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 65 kA at 240 VAC, 35 kA at 480 VAC, 18 kA at 600Y/347 VAC Breaking Capacity, 14-3/0 AWG
Item #: 41384504
Brand: Square D
Model #: BGL26090LU
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
B-Frame Circuit Breaker
Amperage
90
Number of Poles
2
Breaking Capacity
65 kA @ 240 VAC; 35 kA @ 480 VAC; 18 kA @ 600Y/347 VAC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Lug
Mounting Type
Unit Mount
Voltage
600Y/347 VAC
Wire Size (AWG)
14-3/0
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-13
For Use With
Overload and Short Circuit Protection
Standards Met
UL 489; CSA C22.2 No. 5; NMX J-266; IEC/EN 60947-2; IEC/EN60947-5-1; GB 14048.2; NOM; CE Marked
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It
Schneider Electric - 20 Amp, 250 VDC, 1 Pole, Clip Mount C60H-DC Circuit Breaker - Supplementary Protection for Direct Current - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-4, 18-6, 18-8 AWG
Item #: 46117438
Brand: Schneider Electric
Model #: M9U11120
Exact Tooling IR#: 04Features and Benefits
Product Specifications
Circuit Breaker Type
C60H-DC - Supplementary Protection for Direct Current
Amperage
20
Number of Poles
1
Breaking Capacity
10 kA @ 220 VDC; 6 kA @ 250 VDC; 20 kA @ 110 VDC; 5 kA @ 12-250 VDC
Tripping Mechanism
Thermal-Magnetic
Terminal Connection Type
Box Lugs
Mounting Type
Clip
Voltage
250 VDC
Wire Size (AWG)
18-4; 18-6; 18-8
Maximum Operating Temperature (F)
158
Minimum Operating Temperature (F)
-22
Overall Height (Decimal Inch)
3.1900
Overall Length (Decimal Inch)
2.8300
Overall Width (Decimal Inch)
0.7100
For Use With
OEM Panel
Standards Met
UL 1077; IEC; CCC
Reset Actuator Type
Toggle Switch
2% Off All Online Orders
Use Code: 2%OFF
Best Price Guarantee - Email Us A Better Published Price and We'll Beat It