Square D - 80 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56739337
Brand: Square D
Model #: HDL36080C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 80
Number of Poles 3
Breaking Capacity 14 kA @ 600 VAC; 18 kA @ 480 VAC; 20 kA @ 250 VDC; 25 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$2,468.60

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 250 VDC, 600 VAC, 2 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 14-3/0 AWG


Item #: 56748221
Brand: Square D
Model #: HJL26015C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 15
Number of Poles 2
Breaking Capacity 100 kA @ 240 VAC; 20 kA @ 250 VDC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0
Standards Met RoHS Compliant

$3,044.39

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Value Collection - Circuit Breakers Circuit Breaker Type: Miniature Circuit Breaker Amperage: 10


Item #: 66444324
Brand: Value Collection
Exact Tooling IR#: 04

Product Specifications

Circuit Breakers; Circuit Breaker Type: Miniature Circuit Breaker ; Amperage: 10 ; Overall Depth (Decimal Inch): 1/4 ; Overall Height (Inch): 1 ; Overall Width (Decimal Inch): 0.4400 ; Standards Met: SAE J553
Circuit Breaker Type Miniature Circuit Breaker
Amperage 10
Overall Depth (Decimal Inch) 1/4
Overall Height (Inch) 1
Overall Width (Decimal Inch) 0.4400
Standards Met SAE J553

$20.17

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 40 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56745730
Brand: Square D
Model #: HJP36040
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 40
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$3,171.32

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 125 Amp, 250 VDC, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, 25 kA at 600 VAC Breaking Capacity, 14-3/0 (Aluminum), 14-3/0 (Copper) AWG, 110.8mm Deep x 162.6mm High x 104.7mm Wide


Item #: 56745821
Brand: Square D
Model #: HJL36125SOLW
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 125
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Unit Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 14-3/0 (Aluminum); 14-3/0 (Copper)
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
Overall Depth (Decimal Inch) 4.3600
Overall Depth (mm) 110.80
Overall Height (mm) 162.60
Overall Height (Decimal Inch) 6.4000
Overall Width (mm) 104.70
Overall Width (Decimal Inch) 4.1200
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$9,758.03

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41398967
Brand: Square D
Model #: BDA24015Y1
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 15
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$818.72

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 3 Amp, 440 VAC, 2 Pole, Clip, DIN Rail Mount Miniature Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 73mm Deep x 81mm High x 36mm Wide


Item #: 56787757
Brand: Schneider Electric
Model #: 24073
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 3
Number of Poles 2
Breaking Capacity 10 kA @ 400-415 VAC; 20 kA @ 125 VDC; 20 kA @ 230-240 VAC; 30 kA @ 125 VDC; 40 kA @ 250 VDC; 6 kA @ 440 VAC; 6000 A @ 230/400 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Tunnel
Mounting Type Clip; DIN Rail Mount
Voltage 440 VAC
Durability 20000 Cycles
Maximum Operating Temperature (F) 140
Minimum Operating Temperature (F) -13
Overall Depth (mm) 73
Overall Height (mm) 81
Overall Width (mm) 36
For Use With C60 Accessories; C60 Auxiliary
Standards Met EN 60898; EN/IEC 60947-2; RoHS Compliant
Reset Actuator Type Toggle Switch

$288.69

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1200 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56768229
Brand: Square D
Model #: RJF36120U41A
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 1200
Number of Poles 3
Breaking Capacity 100 kA @ 240 VAC; 25 kA @ 600 VAC; 65 kA @ 480 VAC
Tripping Mechanism Electronic
Terminal Connection Type Screw
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0
Standards Met CSA; IEC; UL Listed

$40,984.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Eaton Cutler-Hammer - 175 Amp, 125 VDC, 240 VAC, 3 Pole, Molded Case Circuit Breaker - Thermal Magnetic Trip, 65 kA at 240 VAC Breaking Capacity, 4-4/0 AWG, 3-3/8 Inch Deep x 6 Inch High x 4-1/8 Inch Wide


Item #: 04882809
Brand: Eaton Cutler-Hammer
Model #: ED3175
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 175
Number of Poles 3
Breaking Capacity 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Screw
Voltage 125 VDC; 240 VAC
Wire Size (AWG) 4-4/0
Overall Depth (Decimal Inch) 3.3800
Overall Depth (Inch) 3-3/8
Overall Height (Decimal Inch) 6
Overall Width (Inch) 4-1/8
Overall Width (Decimal Inch) 4.1300
Standards Met CSA Listed; UL Listed 1053; UL Listed 489

$1,968.44

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 2000 Amp, 600 VAC, 3 Pole, Unit Mount Molded Case Circuit Breaker - Electronic Trip, 25 kA at 600 VAC Breaking Capacity, 14.49 Inch Deep x 16.24 Inch High x 16.54 Inch Wide


Item #: 56761398
Brand: Square D
Model #: F36200CU63AE1AB
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 2000
Number of Poles 3
Breaking Capacity 25 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Terminal Nut
Mounting Type Unit Mount
Voltage 600 VAC
Overall Depth (Decimal Inch) 14.4900
Overall Height (Decimal Inch) 16.2400
Overall Width (Decimal Inch) 16.5400
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; HACR; UL Listed
Reset Actuator Type Toggle Switch

$71,605.96

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Schneider Electric - 8 Amp, 480Y/277 Volt, 4 Pole, Clip Mount C60SP Circuit Breaker - Supplementary Protection - Thermal-Magnetic Trip, Multiple Breaking Capacity Ratings, 18-8 AWG


Item #: 46109971
Brand: Schneider Electric
Model #: M9F22408
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type C60SP - Supplementary Protection
Amperage 8
Number of Poles 4
Breaking Capacity 14 kA @ 240 VAC; 10 kA @ 480Y/277 VAC; 6 kA @ 440 VAC; 10 kA @ 415 VAC; 20 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type Clip
Voltage 480Y/277 V
Wire Size (AWG) 18-8
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -22
Overall Height (Decimal Inch) 3.1900
Overall Length (Decimal Inch) 2.8300
Overall Width (Decimal Inch) 2.8400
For Use With OEM Panel
Standards Met UL 1077; IEC; CSA; CCC
Reset Actuator Type Toggle Switch

$423.55

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 40 Amp, 120/240 VAC, 2 Pole, DIN Rail Mounted, Flush Mount, Surface Mount Miniature Circuit Breaker - Thermal Magnetic Trip, 10 kA at 120/240 VAC Breaking Capacity, 14-2 (Aluminum), 14-2 (Copper) AWG, 74mm Deep x 103mm High x 38mm Wide


Item #: 56788409
Brand: Square D
Model #: QOUQ240
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 40
Number of Poles 2
Breaking Capacity 10 kA @ 120/240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type DIN Rail Mounted; Flush Mount; Surface Mount
Voltage 120/240 VAC
Wire Size (AWG) 14-2 (Aluminum); 14-2 (Copper)
Overall Depth (Decimal Inch) 2.9800
Overall Depth (mm) 74
Overall Height (mm) 103
Overall Height (Decimal Inch) 4.0500
Overall Width (mm) 38
Overall Width (Decimal Inch) 1-1/2
For Use With I-Line Panelboards & Switchboards
Standards Met CCC; CSA Certified; Federal Specification W-C 375 b/Gen; UL Listed
Reset Actuator Type Toggle Switch

$146.47

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56742877
Brand: Square D
Model #: JLL36250C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 100 kA @ 480 VAC; 125 kA @ 240 VAC; 20 kA @ 250 VDC; 50 kA @ 600 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0
Standards Met RoHS Compliant

$17,558.58

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 120 VAC, Circuit Breaker


Item #: 49755101
Brand: Square D
Model #: PAMO2
Exact Tooling IR#: 04

Product Specifications

120 VAC, Circuit Breaker -
Voltage 120 VAC
Standards Met CSA; UL Listed

$8,432.62

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 80 Amp, 600Y/347 VAC, 3 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399239
Brand: Square D
Model #: BDA36080
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 80
Number of Poles 3
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 600Y/347 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$1,259.73

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 1 Amp, 250 VAC, 65 VDC, 1 Pole, DIN Rail Mount Circuit Protector - Thermal Magnetic Trip, 16-10 AWG, 64mm Deep x 80mm High x


Item #: 69682524
Brand: Square D
Model #: 9080GCB10
Exact Tooling IR#: 04

Features and Benefits

Circuit protectors are designed for protecting relays, motors, heaters, transformers, solenoids and semiconductors from short circuiting. They protect by monitoring the flow of electricity and detecting any imbalances in the electrical device.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Circuit Protector
Amperage 1
Number of Poles 1
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Box Lugs
Mounting Type DIN Rail Mount
Voltage 250 VAC; 65 VDC
Wire Size (AWG) 16-10
Maximum Operating Temperature (F) 199.94
Minimum Operating Temperature (F) 69.98
Overall Depth (Decimal Inch) 2.5300
Overall Depth (mm) 64
Overall Height (mm) 80
Overall Height (Decimal Inch) 3.1500
Standards Met CSA; UL
Reset Actuator Type Switch

$91.85

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 45 Amp, 480Y/277 VAC, 2 Pole, Panel Mount B-Frame Circuit Breaker - Thermal-Magnetic Trip, 25 kA at 240 VAC, 18 kA at 480Y/277 VAC Breaking Capacity, 14-2/0 AWG


Item #: 41399700
Brand: Square D
Model #: BDA24045Y1
Exact Tooling IR#: 04

Features and Benefits

Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type B-Frame Circuit Breaker
Amperage 45
Number of Poles 2
Breaking Capacity 25 kA @ 240 VAC; 18 kA @ 480Y/277VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type I-Line; Lug
Mounting Type Panel Mount
Voltage 480Y/277 VAC
Wire Size (AWG) 14-2/0
Maximum Operating Temperature (F) 158
Minimum Operating Temperature (F) -13
For Use With Overload and Short Circuit Protection
Standards Met UL 489; CSA C22.2 No. 5; NMX J-266; GB 14048.2; NOM; CE Marked; IEC/EN 60947-2; IEC/EN60947-5-1
Reset Actuator Type Toggle Switch

$816.94

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 250 Amp, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Electronic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56742125
Brand: Square D
Model #: JLL36250CU33X
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Electronic tipping mechanisms provide overload and short-circuit protection with enhanced coordination capabilities and can include integral ground-fault detection.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 250
Number of Poles 3
Breaking Capacity 100 kA @ 480 VAC; 125 kA @ 240 VAC; 50 kA @ 600 VAC
Tripping Mechanism Electronic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 600 VAC
Wire Size (AWG) 3/0

$14,315.66

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 15 Amp, 240 VAC, 1 Pole, Panel Mount Miniature Circuit Breaker - 14-2 AWG


Item #: 56836869
Brand: Square D
Model #: QOU1152100
Exact Tooling IR#: 04

Product Specifications
Circuit Breaker Type Miniature Circuit Breaker
Amperage 15
Number of Poles 1
Terminal Connection Type Box Lugs
Mounting Type Panel Mount
Voltage 240 VAC
Wire Size (AWG) 14-2
For Use With Alarm Switch 1A
Standards Met CSA; IEC; RoHS Compliant; UL Listed

$239.90

2% Off All Online Orders
Use Code: 2%OFF

Best Price Guarantee - Email Us A Better Published Price and We'll Beat It

Square D - 200 Amp, 250 VDC, 600 VAC, 3 Pole, Panel Mount Molded Case Circuit Breaker - Thermal Magnetic Trip, Multiple Breaking Capacity Ratings, 3/0 AWG


Item #: 56743693
Brand: Square D
Model #: JGL36200C
Exact Tooling IR#: 04

Features and Benefits

MCCB (Molded Case Circuit Breakers) are designed to protect against overloads and short circuits in both low and high power applications. Trip settings are adjustable and they are thermal and thermal-magnetically operated. The current rating is up to 2,500 amperes.
Thermal-magnetic tripping mechanisms are designed with both a bi-metal switch and an electromagnet. They perform as a thermal breaker for low level overloads and perform as a magnetic breaker for instantaneous tripping mechanism at high levels.
Product Specifications
Circuit Breaker Type Molded Case Circuit Breaker
Amperage 200
Number of Poles 3
Breaking Capacity 18 kA @ 600 VAC; 20 kA @ 250 VDC; 35 kA @ 480 VAC; 65 kA @ 240 VAC
Tripping Mechanism Thermal-Magnetic
Terminal Connection Type Lug
Mounting Type Panel Mount
Voltage 250 VDC; 600 VAC
Wire Size (AWG) 3/0